Search papers, labs, and topics across Lattice.
This paper introduces the Trajectory Divergence Horizon Decision (TDHD) method, which enhances the reliability of Vision-Language-Action (VLA) models in dual-arm surgical manipulation by adapting execution horizons based on real-time action reliability assessments. By measuring trajectory divergence under noise perturbations, TDHD effectively triggers replanning when necessary, leading to significant performance improvements in surgical tasks. The method was validated on a benchmark with 600 teleoperated demonstrations, achieving a success rate increase from 55% to 80% for tissue manipulation, underscoring the critical role of adaptive execution in surgical robotics.
TDHD boosts surgical manipulation success rates by up to 25% by intelligently adapting action execution based on real-time reliability assessments.
Surgical robotic systems are increasingly being adopted as clinical workload rises, motivating autonomous solutions for repetitive manipulation subtasks. Learning-based controllers improve generalization compared with rule-based and analytic approaches, but most are trained for individual tasks and remain difficult to reuse across procedures. Vision-Language-Action (VLA) models provide a unified framework that integrates visual perception, language grounding, and action generation, offering a promising path toward more composable surgical autonomy. However, existing VLA policies rely on fixed-length open-loop action sequences, where changing scene conditions can lead to accumulated errors and potential risks in surgical manipulation. To mitigate this issue, we formulate surgical VLA deployment as an adaptive execution-horizon decision problem and propose Trajectory Divergence Horizon Decision (TDHD), a test-time mechanism that estimates step-wise action reliability by measuring the divergence between two flow-matching-generated trajectories under small noise perturbations and truncates execution using a dual-threshold rule to trigger timely replanning. We further establish a real-world da Vinci-like dual-arm benchmark with synchronized multi-view perception and language instructions, and collect 600 teleoperated demonstrations across needle (reach, pick, regrasp) and tissue (reach, lift, resection) manipulation suites. On real hardware with 20 trials per task setting, TDHD consistently improves performance over the latest VLA baselines: success increases from 55\% to 60\% for needle manipulation and from 55\% to 80\% for tissue manipulation, with the largest gains observed in the final manipulation stages. These results highlight the importance of adaptive execution control for reliable deployment of VLA models in surgical robotic manipulation.