This study introduces a deep learning framework that utilizes an optimized set of inertial measurement units (IMUs) to estimate bilateral vertical ground reaction forces (vGRFs) in individuals with Parkinson's disease (PD). By training a hybrid CNN-BiLSTM model on data from 61 PD patients and 65 healthy controls, the researchers achieved remarkable intra-subject accuracy ($R^2$ = 0.98) and strong inter-subject generalization ($R^2$ = 0.93 for healthy controls and $R^2$ = 0.91 for PD). The findings reveal that while a minimal setup with two IMUs can still provide robust estimations, optimal accuracy for PD patients is achieved with four IMUs, highlighting the importance of sensor configuration in gait analysis.
Achieving 98% accuracy in estimating ground reaction forces for Parkinson's gait using just two wearable IMUs could revolutionize remote patient monitoring.
Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy ($R^2$ = 0.98) and strong inter-subject generalization ($R^2$ = 0.93 for HC, $R^2$ = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.