Search papers, labs, and topics across Lattice.
This paper introduces ECGLight, a lightweight framework that digitizes paper ECGs and screens for myocardial infarction (MI) using only smartphone photos or scans. By leveraging a compute-light, on-device pipeline, the system reconstructs high-fidelity 12-lead ECG signals and achieves impressive diagnostic accuracy of 95.51% for MI detection on the PTB-XL dataset and 88.89% on the ECG-Matrix dataset. This approach addresses the critical gap in accessibility to AI-driven cardiovascular diagnostics in remote areas with limited computational resources and connectivity.
Legacy paper ECGs can now be transformed into actionable diagnostic tools in under 30 seconds, even in resource-constrained settings.
Electrocardiography (ECG) is one of the most widely used tests for diagnosing cardiovascular disease. Yet several remote clinics still utilize paper ECG printouts for their analysis due to limited connectivity and computational capacity. As a result, vast numbers of physical ECGs obtained in remote areas still remain incapable of being accessed by contemporary artificial-intelligence (AI)-based decision support as they require high computational resources or strong high-speed internet connectivity. This causes several cases where conditions like acute coronary occlusion (ACS) is overlooked and reperfusion therapy delayed. Although prior work has tackled digitization and diagnosis separately, and utilized advanced AI models for them, there still remains a lack of a compute-light, on-device framework that reconstructs paper ECGs at high fidelity, while accurately supporting multiple clinically relevant endpoints. We address this need with an end-to-end lightweight on-device digitization-to-diagnosis pipeline that converts a smartphone photo or scan of a paper ECG into a calibrated 12-lead signal and screens for Myocardial Infarction (MI) pathologies, with SHapley Additive exPlanations (SHAP) to support interpretability. Trained and evaluated on 21,799 ECGs from the PTB-XL dataset and further validated on hospital-acquired ECG-Matrix dataset, the complete system runs in <30 s per ECG on CPU-only resources, achieving 95.51% accuracy (F1 = 0.9519) for MI detection on PTB-XL and 88.89% accuracy (F1 = 0.8862) for OMI detection on ECG-Matrix. This work showcases that legacy paper records can be reliably democratized in any part of the world, providing a scalable decision support when digital ECG export, connectivity, or high-end compute are unavailable