Search papers, labs, and topics across Lattice.
This paper introduces TriDP-PTM, a three-stage pre-training model for radar-based cardiac sensing that balances distortion and perception by comparing a direct radar-to-task path against an indirect radar-to-ECG-to-task path. The key insight is that optimal downstream clinical accuracy is achieved in a "coopetitive" stage where distortion and perception losses are appropriately weighted. Experiments on a 30-subject dataset show the indirect path consistently outperforms the direct path, achieving significant improvements in waveform segmentation, classification accuracy, and blood pressure regression.
Counterintuitively, letting radar cardiac sensors learn to mimic ECGs first yields far better performance on downstream tasks like blood pressure regression and waveform segmentation than directly training on those tasks.
Cardiovascular diseases (CVDs) remain a leading cause of death globally, necessitating continuous, accurate non-invasive cardiac monitoring. While non-contact radar-based approaches show great promise, they often employ a single "distortion-driven" or "perception-driven" paradigm, frequently facing a trade-off between "low distortion but weak semantic information" and "high perceptual fidelity but poor interpretability." To address this, we propose a Three-stage Distortion-Perception Pre-Training Model (TriDP-PTM), a radar-based multi-scale fusion dual-path framework that systematically compares the "direct radar-to-task" path against an "indirect radar-to-ECG-to-task" path. By integrating an ECG generator with a feature discriminator to form a composite loss function, our approach effectively incorporates medical priors - such as ECG morphology and rhythm - into downstream tasks. Through empirical analysis, we reveal that this trade-off manifests in three distinct phases (Positive-Sum, Coopetitive, and Negative-Sum), showing optimal downstream clinical accuracy typically emerges in the coopetitive stage. Extensive experiments on a dataset involving 30 subjects across 5 physiological states reveal that the indirect path consistently outperforms the direct path in diverse tasks, achieving 0.80 mean IoU in waveform segmentation, 98.3% average classification accuracy across four tasks, and a 56% MAE reduction in blood pressure regression compared to the strongest baselines. These findings validate our framework and indicate that, within the indirect radar-to-ECG pathway, appropriately weighting distortion and perception losses to operate in the coopetitive regime is critical for achieving both clinically interpretable ECG morphology and strong downstream accuracy in non-contact cardiac monitoring.