This paper introduces a novel approach to digital breast tomosynthesis (DBT) reconstruction by employing exact and calibrated diffusion methods to address the challenges of limited-angle imaging. The authors replace traditional proximal updates in conditional diffusion sampling with exact Euclidean projections, achieving a significant speedup and ensuring data consistency while maintaining perceptual quality. Their method not only improves fidelity in reconstructed images but also provides calibrated uncertainty estimates, outperforming existing techniques in error metrics on patient-derived breast phantoms.
Achieving data-consistent and uncertainty-calibrated reconstructions in digital breast tomosynthesis could revolutionize diagnostic imaging accuracy and reliability.
Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, $25^{\circ}$ protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge. Conditional diffusion priors achieve strong perceptual quality here but leave three clinical obstacles: inexact data consistency, unlocalized hallucination, and uncalibrated uncertainty. We enforce measurements exactly by replacing the per-step proximal update of a conditional diffusion sampler with exact Euclidean projection onto the data-consistent set, computed via an $m$-dimensional dual system with a one-time Gram matrix $AA^{\top}$ factorization. This projection costs 4.5 ms per step (a $248\times$ speedup) and drives the data residual to the double-precision floor ($2.4\times10^{-13}$). We prove it is the $蟻\to0$ limit of the proximal step, provide a no-harm theorem, and show that exactly consistent sample ensembles have variance supported on null($A$). Thus, the mean's entire error lies in the unmeasured subspace covered by the uncertainty map. On patient-derived breast phantoms, this improves fidelity at no depth-resolution cost. Conversely, a proximal step applied post-update degrades quality, isolating the consistency step's placement as decisive. Isotonic recalibration brings the ensemble spread to a calibrated error scale (expected calibration error $0.029\to0.008$; standardized error $4.7\to0.96$), ranking errors better than the pure prior. We also repair a 20.3% adjoint mismatch in a deployed projector via a materialized operator of record. This is the first data-consistent, uncertainty-calibrated learned reconstruction for limited-angle DBT. The solver naturally relaxes to discrepancy-ball and maximum-a-posteriori modes for noisy measurements.