Search papers, labs, and topics across Lattice.
The authors introduce STR-Net, a multi-task deep learning framework that performs bone-loss screening, severity sub-classification, and T-score regression directly from routine knee radiographs. This approach leverages existing imaging data to opportunistically identify patients at risk for osteoporosis and osteopenia without requiring additional DXA scans. STR-Net achieves an AUROC of 0.933 for binary screening and a Pearson correlation of 0.801 with DXA-measured T-scores, demonstrating its potential for efficient and accessible bone health assessment.
Repurposing routine knee X-rays for AI-powered bone-loss screening could dramatically expand access to early osteoporosis detection.
Background: Osteoporosis and osteopenia are often undiagnosed until fragility fractures occur. Dual-energy X-ray absorptiometry (DXA) is the reference standard for bone mineral density (BMD) assessment, but access remains limited. Knee radiographs are obtained at high volume for osteoarthritis evaluation and may offer an opportunity for opportunistic bone-loss screening. Objective: To develop and evaluate a multi-task deep learning system for opportunistic bone-loss screening from routine knee radiographs without additional imaging or patient visits. Methods: We developed STR-Net, a multi-task framework for single-channel grayscale knee radiographs. The model includes a shared backbone, global average pooling feature aggregation, a shared neck, and a task-aware representation routing module connected to three task-specific heads: binary screening (Normal vs. Bone Loss), severity sub-classification (Osteopenia vs. Osteoporosis), and weakly coupled T-score regression with optional clinical variables. A sensitivity-constrained threshold optimization strategy (minimum sensitivity>= 0.86) was applied. The dataset included 1,570 knee radiographs, split at the patient level into training (n=1,120), validation (n=226), and test (n=224) sets. Results: On the held-out test set, STR-Net achieved an AUROC of 0.933, sensitivity of 0.904, specificity of 0.773, and AUPRC of 0.956 for binary screening. Severity sub-classification achieved an AUROC of 0.898. The T-score regression branch showed a Pearson correlation of 0.801 with DXA-measured T-scores in a pilot subset (n=31), with MAE of 0.279 and RMSE of 0.347. Conclusions: STR-Net enables single-pass bone-loss screening, severity stratification, and quantitative T-score estimation from routine knee radiographs. Prospective clinical validation is needed before deployment.