Search papers, labs, and topics across Lattice.
This study introduces CMRVision, a foundation model specifically designed for cardiac magnetic resonance (CMR) image analysis, trained on a diverse dataset of 36 million images using DINOv3-style self-supervised learning. The model was systematically evaluated on multi-task segmentation and cine view classification, demonstrating significant performance improvements over existing baselines, particularly in myocardium segmentation across various imaging sequences. Key results include achieving Dice scores of 0.940-0.967 for left ventricle segmentation and an average accuracy of 0.906 in cine view classification, showcasing CMRVision's robustness and generalizability in clinical applications.
CMRVision outperforms existing models in cardiac MRI analysis, achieving remarkable segmentation accuracy and setting a new benchmark for multi-task performance in this domain.
Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.