Search papers, labs, and topics across Lattice.
This paper introduces Distributionally Robust Conformal Safety Screening (DR-CSS), a novel policy-agnostic framework designed to evaluate the safety of new voltage control policies in active distribution grids prior to deployment. By leveraging historical data and a nominal simulator, DR-CSS constructs conformal safety intervals that account for both historical simulation errors and potential closed-loop interactions with existing controllers. Experimental results on IEEE test systems demonstrate that DR-CSS successfully identifies all unsafe scenarios while minimizing false alarms in safe conditions, enhancing decision-making for policy deployment.
DR-CSS not only identifies all unsafe voltage control scenarios but also adapts safety intervals to reduce false warnings, revolutionizing pre-deployment assessments in active distribution grids.
Deploying a new control policy for voltage control in active distribution grids requires evidence that physical limits will be satisfied before the policy is tested on the physical grid. This assessment is difficult for two reasons. First, simulations cannot capture every disturbance, modeling error, and device interaction present in the real grid. Second, historical measurements reflect operation under existing control policies, whereas a new policy may drive the grid into different operating conditions. To address these challenges, we propose Distributionally Robust Conformal Safety Screening (DR-CSS), a policy-agnostic framework for pre-deployment, scenario-by-scenario screening of a new control policy using historical data and a nominal simulator. For each new scenario, the simulator predicts a future voltage trajectory for the whole grid; DR-CSS then constructs a conformal safety interval around this prediction using historical simulation-to-reality errors. The interval is further enlarged to account for closed-loop changes induced by the deployment of the new policy and its interactions with the remaining controllers. To the best of our knowledge, DR-CSS is the first framework in power systems to combine historical data from an existing control policy with an imperfect simulator for pre-deployment safety screening of a new policy. Experiments on the IEEE 33-bus and IEEE 141-bus systems evaluate the deployment of learning-based voltage control policies and show that DR-CSS identifies all unsafe test scenarios. To reduce unnecessary warnings on safe scenarios, we adapt the safety intervals to different operating conditions and gradually introduce new policies with recalibration after each stage. These extensions increase the informational value of the safety screening and support safer deployment decisions in active distribution grids.